| 1888 Articles Home | Business Articles | Brands Articles | Brands RSS | ![]() |
||
Blowers and Positive Pressure Fans |
||||
Buffalo Blower Co. makes low Profile Positive Pressure Ventilators that have been designed to fit in tight compartments ans small spaces without scarificing performance or features. These compact ventilation blowers are available is both gasoline driven conviguration and with 115/230V single phase electric motor.
Electric smoke ejectors (negative pressure ventilation) can be used for smoke removal but this has proven to be inferior to positive pressure ventilation.
What makes Positive Pressure Ventilation superior to negative pressure ?
* The risk of injury from the engaged structure is reduced while placing the fan in operation.
* Positive pressure ventilation is faster to set up and requires fewer personnel.
* The Positive Pressure Blower has a self contained power source, while electric fans require cords and adaptors.
* Smoke and heat is removed from all levels of the structure unlike negative pressure which can result in localized extraction.
* Quicker results. After initial knockdown, positive pressure ventilation can be initiated and will show immediate improvements in the interior conditions.
* It allows replacement of contaminants with vital cooler, cleaner air - especially in sealed or windowless buildings. It's also very effective in large and compartmentalized buildings, warehouses, schools, etc.
* Quick results allow firefighters faster entry due to lower heat levels and improved visibility.
The following criteria should be considered for effective use of Positive Ventilation:
- The cone of air must cover the intake opening. The fan must be placed the correct distance from the structure such as that the cone of air forms a seal around the opening.
- The size and location of the discharge is important. The discharge, if at all possible should be as high and far away from the intake as is practical. The discharge size should be between 3/4 to 1/2 times the intake. This may not always be possible as the fire may have already dictated discharge locations and sizes; but whenever there is a choice, the above criteria should be used.
- It is important to control the ait flow between the intake and discharge. Positive pressure ventilation can move air long distances if proper control is maintained by opening and closing doors, windows, etc. It is important that firefighters understand not to open the structure too much: ie breaking windows, etc.
The standard features of Buffalo Blower Co. Positive Pressure Ventilators include: fold down "T" handle; 8" pneumatic tires with full width axle; a "tilt and lock" device that allows the unit to be angled 20 degrees up or down with infinite positions in between; sturdy and light 1 inch wrap around frame. Explosion proof electric motors are available as drivers too.
The optimum ventilator placement distance on most 6'6" doors is about five to six feet away. If placement is too close, the seal won't be achieved. If placement is too far away, the cone of air will be hitting well outside the opening.
About Author
Oleg Tchetchel
Canadian Industrial Air Systems Designer
Buffalo Blower Co.
http://buffaloblower.com/oem/index.html
http://buffaloblower.com/heat/index.html
Article Source:
http://www.1888articles.com
Other Related Articles Boost Credit Score and Lower Premiums! by Norris Rios How College Students Find Insurance Savings by Norris Rios Use a external monitor for your laptop by Herowei Blowers and Positive Pressure Fans by Canadian Air Systems Quick Bad Credit Loans- Immediate funds to resolve all your needs by Angela Kane Learning To Use Internet Marketing To Boost Profits and Increase Your Business by Nicko |